• No Additive Tube
  • No Additive Tube

No Additive Tube

No additive tube is used in blood collection and storage for biochemistry, immunology, serology, test of various kinds of virus and microelement in medical inspection. With special treatment on the inner surface, it's extremely smooth for normal activity of thrombocyte and unhindered clotting, which prevents hemolysis or adhesion of blood corpuscle or fibrin to the inner surface. It can provide enough pollution-free serum samples for clinical test, and maintain the normal compositions of serum for a long time. Moreover, it's helpful to serum reinspection with good repeatability.

Time for complete clot retraction: 1.5-2h

Centrifugation speed: 3500-4000r/m

Centrifugation time: 5min

Recommended storage temperature: 4-25℃


Product Overview

Product Advantage

KANGJIAN Medical supplies a high quality product to reduce the variation of blood samples before analysis and error for the clinic labs, We have passedIS013485, ISO901 and havealready got the CEF certificate for the blood collection tubes, W e havestrict procedural management for theprocess from purchasing of raw material to the sales of product.

Full automatic production line, After-labeling process,Image detection to keep reliable quality.

Good compatibility makes it fit different biochemical analyzer, immunity analyzer and blood analyzer.

Full range of tubes available, Ø13×75mm, Ø13×100mm, Ø16×100mm,Ø9×120mm tubes available.

In the clinictest of human venous blood samples, we divide the tubes to be serum bloodtubes, Plasma blood tubes and whole blood tubes based on different test.

We can customize specialized collection volume, labels and altitude based on detailed requirements.

We can supply specialized training and technique support for the distributors and final customers.

Safety Cap

Selection of high quality synthetic butyl rubber stopper, very suitable for automaticanalyzer puncture sampling,it airtightness, puncture force is small very few drops not plug the hole, and pin the needle.

Special rubber plug configuration, to reduce the wear of the puncture needle,Puncture needle life is more than twice the use of ordinary rubber stopper.

Patented design, butyl rubber stopper and safety cap with close, does not occur flip, separation phenomenon, open, coats easy and pleasant.

Suitable for all kinds of off-hat centrifuge and decapper.

Head cap colors meet internationally accepted standards.

High Quality Tube

The use of high-quality PET material, stable nature, and have good air tightness.

PET tube inner wall using the United States imported reagent silicification treatment, the surface is extremely smooth, to avoid cell wall.

The inner wall uses a biomimetic membrane treatment technology to provide a comprehensive and detailed protection program for blood cells.

High Efficiency

Selection ofJapan's SEKISUI production of coagulants and serum separation Gel, so that the blood samples more original, test results more accurate.

Use high-quality inert separation gel, no interference of the blood of physical and chemistry performance.

Get clear, transparent and clean serum specimens after fast centrifugation.

High temperature (45°C) and easy to freeze storage, with a stable nature, after centrifugation rarely appear "oil droplets" phenomenon.

Could be Gamma sterilized.

High Quality Additives

Use high-quality international renowned brand additive, import Swiss precision spray equipment, the medical industry leader.

The variety of additives is complete, the variety of forms, the main use of spray drying technology,so that the anticoagulant effect of uniform mild thorough.

Set the vacuum accurately, to ensure that the proportion of blood samples and additives accurate.

Customize the Label

Depending on the customer's requirementsdifferent materials and labels with specific identification can be customized. Prefabricated bar code easy toidentify,more wearable.

Tailable label tubing and bar code label tubes are prefixed with custom labels.

Classification of Vacuum Tubes

Inthe clinicalexperimentfrom the venousblood samples, thecollection tubesdividedinto Serum bloodtubes, plasma blood tubs and whole blood tubes according to different request of the blood specimen.

Serum blood tubed: no additive (red cap), clot activator (orange cap), Separation gel (yellow cap).

Plasma blood tubes: PT tube (blue cap), Heparin tube (green cap), Oxalate tube (grey cap), Nucleic acid detection tube (pink cap).

Whole blood tubs: Blood routine tube (purple cap), ESR tube (black cap) and Dynamic blood sedimentation tube (black cap).

Specifications

REF

Original REF.

Tube Specification

Nominal Volume

Additive

Tube Material

Qty/Cs

0104-0311

KJ030Z

Ø13×75mm

3ml

Clot Activator

Glass

100PCS×18

0104-0312

PET

100PCS×18

0104-0411

KJ040Z

Ø13×75mm

4ml

Clot Activator

Glass

100PCS×18

0104-0412

PET

100PCS×18

0104-0511

KJ050Z

Ø13×75mm

5ml

Clot Activator

Glass

100PCS×18

0104-0512

PET

100PCS×18

0104-0521

KJ0501Z

Ø13×100mm

5ml

Clot Activator

Glass

100PCS×12

0104-0522

PET

100PCS×18

0104-0621

KJ0601Z

Ø13×100mm

6ml

Clot Activator

Glass

100PCS×12

0104-0622

PET

100PCS×18

0104-0721

KJ0701Z

Ø13×100mm

7ml

Clot Activator

Glass

100PCS×12

0104-0722

PET

100PCS×18

0104-0831

KJ0801Z

Ø16×100mm

8ml

Clot Activator

Glass

100PCS×12

0104-0832

PET

100PCS×12

0104-0931

KJ0901Z

Ø16×100mm

9ml

Clot Activator

Glass

100PCS×12

0104-0932

PET

100PCS×12

0104-1031

KJ1002Z

Ø16×100mm

10ml

Clot Activator

Glass

100PCS×12

0104-1032

PET

100PCS×12

Label:
Product Video
Label: