Clot activator tube is used in the blood collection for biochemistry and immunology in medical inspection. It is suitable for wide range of operating temperature. With special treatment, the tube inner surface is very smooth where high-quality coagulant sprays uniformly. The blood sample will completely contact with coagulant and clot within 5-8min. High-quality serum thus is obtained by later centrifugation, free from the cracking of blood corpuscle, hemolysis, separation of fibrin protein, etc. Hence the serum can meet the requirements of fast clinic and emergency serum test.
◆ Time for complete clot retraction: 20-25min
◆ Centrifugation time: 5min
◆ Centrifugation speed: 3500-4000r/m
◆ Recommended storage temperature: 4-25℃
Product Advantage
◎ KANGIAN Medical supplies a high quality product to reduce the variation of blood samples before analysis and error for the clinic labs, We have passedIS013485, ISO901 and havealready got the CEF certificate for the blood collection tubes, W e havestrict procedural management for theprocess from purchasing of raw material to the sales of product.
◎ Full automatic production line, After-labeling process,Image detection to keep reliable quality.
◎ Good compatibility makes it fit different biochemical analyzer, immunity analyzer and blood analyzer.
◎ Full range of tubes available, Ø13×75mm, Ø13×100mm, Ø16×100mm,Ø9×120mm tubes available.
◎ In the clinictest of human venous blood samples, we divide the tubes to be serum bloodtubes, Plasma blood tubes and whole blood tubes based on different test.
◎ We can customize specialized collection volume, labels and altitude based on detailed requirements.
◎ We can supply specialized training and technique support for the distributors and final customers.
Safety Cap
◆ Selection of high quality synthetic butyl rubber stopper, very suitable for automaticanalyzer puncture sampling,it airtightness, puncture force is small very few drops not plug the hole, and pin the needle.
◆ Special rubber plug configuration, to reduce the wear of the puncture needle,Puncture needle life is more than twice the use of ordinary rubber stopper.
◆ Patented design, butyl rubber stopper and safety cap with close, does not occur flip, separation phenomenon, open, coats easy and pleasant.
◆ Suitable for all kinds of off-hat centrifuge and decapper.
◆ Head cap colors meet internationally accepted standards.
High Quality Tube
◆ The use of high-quality PET material, stable nature, and have good air tightness.
◆ PET tube inner wall using the United States imported reagent silicification treatment, the surface is extremely smooth, to avoid cell wall.
◆ The inner wall uses a biomimetic membrane treatment technology to provide a comprehensive and detailed protection program for blood cells.
High Efficiency
◆ Selection ofJapan's SEKISUI production of coagulants and serum separation Gel, so that the blood samples more original, test results more accurate.
◆ Use high-quality inert separation gel, no interference of the blood of physical and chemistry performance.
◆ Get clear, transparent and clean serum specimens after fast centrifugation.
◆ High temperature (45°C) and easy to freeze storage, with a stable nature, after centrifugation rarely appear "oil droplets" phenomenon.
◆ Could be Gamma sterilized.
High Quality Additives
◆ Use high-quality international renowned brand additive, import Swiss precision spray equipment, the medical industry leader.
◆ The variety of additives is complete, the variety of forms, the main use of spray drying technology,so that the anticoagulant effect of uniform mild thorough.
◆ Set the vacuum accurately, to ensure that the proportion of blood samples and additives accurate.
Customize the Label
◆ Depending on the customer's requirementsdifferent materials and labels with specific identification can be customized. Prefabricated bar code easy toidentify,more wearable.
◆ Tailable label tubing and bar code label tubes are prefixed with custom labels.
REF | Original REF. | Tube Specification | Nominal Volume | Additive | Tube Material | Qty/Cs |
---|---|---|---|---|---|---|
0105-0311 | KJ030Z | Ø13×75mm | 3ml | Clot Activator | Glass | 100PCS×18 |
0105-0312 | PET | 100PCS×18 | ||||
0105-0411 | KJ040Z | Ø13×75mm | 4ml | Clot Activator | Glass | 100PCS×18 |
0105-0412 | PET | 100PCS×18 | ||||
0105-0511 | KJ050Z | Ø13×75mm | 5ml | Clot Activator | Glass | 100PCS×18 |
0105-0512 | PET | 100PCS×18 | ||||
0105-0521 | KJ0501Z | Ø13×100mm | 5ml | Clot Activator | Glass | 100PCS×12 |
0105-0522 | PET | 100PCS×18 | ||||
0105-0621 | KJ0601Z | Ø13×100mm | 6ml | Clot Activator | Glass | 100PCS×12 |
0105-0622 | PET | 100PCS×18 | ||||
0105-0721 | KJ0701Z | Ø13×100mm | 7ml | Clot Activator | Glass | 100PCS×12 |
0105-0722 | PET | 100PCS×18 | ||||
0105-0831 | KJ0801Z | Ø16×100mm | 8ml | Clot Activator | Glass | 100PCS×12 |
0105-0832 | PET | 100PCS×12 | ||||
0105-0931 | KJ0901Z | Ø16×100mm | 9ml | Clot Activator | Glass | 100PCS×12 |
0105-0932 | PET | 100PCS×12 | ||||
0105-1031 | KJ1002Z | Ø16×100mm | 10ml | Clot Activator | Glass | 100PCS×12 |
0105-1032 | PET | 100PCS×12 |